Pulmonary compliance

Pulmonary compliance (or lung compliance) is a measure of the lung's ability to stretch and expand. In clinical practice it is separated into two different measurements, static compliance and dynamic compliance. Static lung compliance is the change in volume for any given applied pressure.[1] Dynamic lung compliance is the compliance of the lung at any given time during actual movement of air.

Low compliance indicates a stiff lung (one with high elastic recoil) and can be thought of as a thick balloon - this is the case often seen in fibrosis. High compliance indicates a pliable lung (one with low elastic recoil) and can be thought of as a grocery bag - this is the case often seen in emphysema. Compliance is highest at moderate lung volumes, and much lower at volumes which are very low or very high. The compliance of the lungs demonstrate hysteresis; that is, the compliance is different on inspiration and expiration for identical volumes.

Calculation

Pulmonary compliance is calculated using the following equation, where ΔV is the change in volume, and ΔP is the change in pleural pressure:

For example, if a patient inhales 500 mL of air from a spirometer with an intrapleural pressure before inspiration of – 5 cm H2O and -10 cm H2O at the end of inspiration. Then:

Static compliance (Cstat)

Static compliance represents pulmonary compliance during periods without gas flow, such as during an inspiratory pause. It can be calculated with the formula:

where Pplat = plateau pressure. Pplat is measured at the end of inhalation and prior to exhalation using an inspiratory hold maneuver. During this maneuver, airflow is transiently (~0.5 sec) discontinued, which eliminates the effects of airway resistance. Pplat is never > PIP and is typically < 3-5 cmH2O lower than PIP when airway resistance is not elevated.

Dynamic compliance (Cdyn)

Dynamic compliance represents pulmonary compliance during periods of gas flow, such as during active inspiration. Dynamic compliance is always lower than or equal to static lung compliance because PIP-PEEP is always greater than Pplat-PEEP. It can be calculated using the following equation, where Cdyn = Dynamic compliance; VT = tidal volume; PIP = Peak inspiratory pressure (the maximum pressure during inspiration); PEEP = Positive End Expiratory Pressure:

Alterations in airway resistance, lung compliance and chest wall compliance influence Cdyn.

Clinical significance

It is in fact an important measurement in respiratory physiology.[2][3][4]

Pulmonary surfactant increases compliance by decreasing the surface tension of water. The internal surface of the alveolus is covered with a thin coat of fluid. The water in this fluid has a high surface tension, and provides a force that could collapse the alveolus. The presence of surfactant in this fluid breaks up the surface tension of water, making it less likely that the alveolus can collapse inward. If the alveolus were to collapse, a great force would be required to open it, meaning that compliance would decrease drastically.

Functional significance of abnormally high or low compliance

Low compliance indicates a stiff lung and means extra work is required to bring in a normal volume of air. This occurs as the lungs in this case become fibrotic, lose their distensibility and become stiffer.

In a highly compliant lung, as in emphysema, the elastic tissue is damaged by enzymes. These enzymes are secreted by leukocytes (white blood cells) in response to a variety of inhaled irritants, such as cigarette smoke. Patients with emphysema have a very high lung compliance due to the poor elastic recoil. They have extreme difficulty exhaling air. In this condition extra work is required to get air out of the lungs. In addition, patients often have difficulties inhaling air as well. This is due to the fact that a high compliant lung results in many collapsed alveoli which makes inflation difficult. Compliance also increases with increasing age.

Compliance decreases in the following cases:

References

  1. Lung compliance at the US National Library of Medicine Medical Subject Headings (MeSH)
  2. Compliance
  3. Nikischin W, Gerhardt T, Everett R, Bancalari E (1998). "A new method to analyze lung compliance when pressure-volume relationship is nonlinear.". Am J Respir Crit Care Med. 158 (4): 1052–60. doi:10.1164/ajrccm.158.4.9801011. PMID 9769260. article
  4. Physiology: 4/4ch2/s4ch2_21 - Essentials of Human Physiology
  5. J.B.West, Respiratory Physiology, 9th edition,page 99
This article is issued from Wikipedia - version of the 9/10/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.